The tank light is used to illuminate the inside of a vessel while brewing or cleaning. It mounts to a 2 in. TC fitting. A standard 120 volt circuit and a 50 watt bulb are required. Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information. Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More
The low level sensor is an on/off float switch. The float should mount at the low level limit of a tank. Most commonly used in a hot liquor tank. Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 60.00 PSIG @ 200°F
TYPE SR-H Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 75PSIG @ 75°F Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 110.00 PSIG @ 200°F
TYPE AXIUS SC Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 1 1/2IN TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 130.0 PSIG @ 300°F Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 88.3 PSIG @ 72°F
SR-H TYPE Learn More
The rupture disc fits between 2IN TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Replace the disk every 5-6 years depending on the use of the tank to ensure superior performance. Learn More
The P.R.V. attaches to a 3IN TC vent.
Valve relieves pressure as the fluid level rises while filling a tank
Valve relieves vacuum as the fluid level drops while emptying a tank
Seals under equal pressure
Full body 316 stainless steel construction
1/4" FNPT connection for gas inlet, plug is included
Vacuum break: , 0.1 PSI
Pressure relief: 0.9 PSI
Maximum temperature and pressure rating: 3 PSI @ 70°F
Maximum flow rate: 500 GPM Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat.
DIA X 1IN DIA SLIP JOINT BOTTOM SPRAY PATTERN 316L Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More