Thermometer face is 3IN. diameter and has a 1/2 in. MNPT threaded connection. 12IN stem. Rear mounted. Temperature range reads from 0 to 250 deg. F Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 110.00 PSIG @ 200°F
TYPE AXIUS SC Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 1 1/2IN TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 130.0 PSIG @ 300°F Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information. Learn More
The Sani-Spin is used much the same way as a C.I.P. sprayball. The advantage of the Sani-Spin is the force of it’s spinning action and the minimal volume it requires. For example, the optimum operating condition for a C.I.P. sprayball is 40 GPM @ 25 PSI; where as the Sani-Spin requires just 25 GPM @ 30 PSI. Learn More
The Sani-Spin is used much the same way as a C.I.P. sprayball. The advantage of the Sani-Spin is the force of it’s spinning action and the minimal volume it requires. For example, the optimum operating condition for a C.I.P. sprayball is 40 GPM @ 25 PSI; where as the Sani-Spin requires just 25 GPM @ 30 PSI. Learn More
The tee assembly is used to inject gas into the product. A hollow capped tube of cintered stainless is welded to a TC ferrule and clamped to a customized TC tee. This assembly includes a special tee, cintered stone, check valve, 3/8" hose barb, clamp and gasket. 304 SS mat. Learn More
The 3-way level gauge valve will mount to a 1-1/2 in. TC at the base of a ICC NW level gauge system. This valve allows you to isolate the level gauge. 304 SS mat. The sight tube is translucent PFA Teflon. Make sure the tube insert is used at all tubing connections.
Compression insert 1/2" for 5/8 for PTFE Tube
.5IN OD for 5/8IN PTFE Tube Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
The P.R.V. attaches to a 2 in. TC vent or P.A.M. assembly. The valve is easy to take apart and clean. 15 lb. and 25 lb. pressure springs are available. Relief pressure can be adjusted down 5 lb. The valve will open at 0.089 lb. of vacumm. Full stainless steel body construction. Learn More
The tank light is used to illuminate the inside of a vessel while brewing or cleaning. It mounts to a 2 in. TC fitting. A standard 120 volt circuit and a 50 watt bulb are required. Learn More
It produces 1,568 lumens. 1 per box. Kit includes: Stainless steel mounting bracket and hardware. - Bracket for surface mount only. Hardwired. Learn More
Tubes are designed for ICC NW varying capacity storage tanks. Please consult chart for correct size, questions please call (503) 468-6560. Our tube forumla changed in 2021. Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
The Fuji controller receives information from the temperature sensor and sends open/close signals to the Heat Transfer Jacket solenoid valve. It can also operate direct fire Burners/Immersion Heaters/Etc. Learn More