The hi-low level control is used to regulate wort receiver levels. Commonly used on both the brewpub open wort receiver and the enclosed airless grant. Wetted parts are 316 Stainless Steel. Learn More
The Sani-Spin is used much the same way as a C.I.P. sprayball. The advantage of the Sani-Spin is the force of it’s spinning action and the minimal volume it requires. For example, the optimum operating condition for a C.I.P. sprayball is 40 GPM @ 25 PSI; where as the Sani-Spin requires just 25 GPM @ 30 PSI. Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
Thermometer face is 3IN. diameter and has a 1/2 in. MNPT threaded connection. 4IN stem. Rear mounted. Temperature range reads from 0 to 250 deg. F Learn More
Thermometer face is 3IN. diameter and has a 1/2 in. MNPT threaded connection. 12IN stem. Rear mounted. Temperature range reads from 0 to 250 deg. F Learn More
Thermometer face is 5IN. diameter and has a 1/2 in. MNPT threaded connection. 9IN stem. Rear mounted. Temperature range reads from 0 to 250 deg. F Learn More
It produces 1,568 lumens. 1 per box. Kit includes: Stainless steel mounting bracket and hardware. - Bracket for surface mount only. Hardwired. Learn More
The in-line site glass is used for product viewing. The site glass has a TC ferrule on each end. The clear portion is either Pyrex or glass. One end unscrews to replace lens and gaskets. Learn More
The P.R.V. attaches to a 2 in. TC vent or P.A.M. assembly. The valve is easy to take apart and clean. 15 lb. and 25 lb. pressure springs are available. Relief pressure can be adjusted down 5 lb. The valve will open at 0.089 lb. of vacumm. Full stainless steel body construction. Learn More
The Fuji controller receives information from the temperature sensor and sends open/close signals to the Heat Transfer Jacket solenoid valve. It can also operate direct fire Burners/Immersion Heaters/Etc. Learn More
Thermometer face is 3IN. diameter and has a 1/2 in. MNPT threaded connection. 4IN stem. Rear mounted. Temperature range reads from 0 to 250 deg. F Learn More
The P.R.V. attaches to a 3IN TC vent.
Valve relieves pressure as the fluid level rises while filling a tank
Valve relieves vacuum as the fluid level drops while emptying a tank
Seals under equal pressure
Full body 316 stainless steel construction
1/4" FNPT connection for gas inlet, plug is included
Vacuum break: , 0.1 PSI
Pressure relief: 0.9 PSI
Maximum temperature and pressure rating: 3 PSI @ 70°F
Maximum flow rate: 500 GPM Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
The clear TC cap attaches to a TC ferrule for viewing. These caps are not designed to be used under pressure. Caution must be used in tightening the clamp as the cap can crack. Learn More
The clear TC cap attaches to a TC ferrule for viewing. These caps are not designed to be used under pressure. Caution must be used in tightening the clamp as the cap can crack. Learn More
The clear TC cap attaches to a TC ferrule for viewing. These caps are not designed to be used under pressure. Caution must be used in tightening the clamp as the cap can crack. Learn More