The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
The Sani-Spin is used much the same way as a C.I.P. sprayball. The advantage of the Sani-Spin is the force of it’s spinning action and the minimal volume it requires. For example, the optimum operating condition for a C.I.P. sprayball is 40 GPM @ 25 PSI; where as the Sani-Spin requires just 25 GPM @ 30 PSI. Learn More
The clear TC cap attaches to a TC ferrule for viewing. These caps are not designed to be used under pressure. Caution must be used in tightening the clamp as the cap can crack. Learn More
The hi-low level control is used to regulate wort receiver levels. Commonly used on both the brewpub open wort receiver and the enclosed airless grant. Wetted parts are 316 Stainless Steel. Learn More
The 3-way level gauge valve will mount to a 1-1/2 in. TC at the base of a ICC NW level gauge system. This valve allows you to isolate the level gauge. 304 SS mat. The sight tube is translucent PFA Teflon. Make sure the tube insert is used at all tubing connections.
Compression insert 1/2" for 5/8 for PTFE Tube
.5IN OD for 5/8IN PTFE Tube Learn More
The Sani-Spin is used much the same way as a C.I.P. sprayball. The advantage of the Sani-Spin is the force of it’s spinning action and the minimal volume it requires. For example, the optimum operating condition for a C.I.P. sprayball is 40 GPM @ 25 PSI; where as the Sani-Spin requires just 25 GPM @ 30 PSI. Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat.
DIA X 1IN DIA SLIP JOINT BOTTOM SPRAY PATTERN 316L Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
The hi-low level control is used to regulate wort receiver levels. Commonly used on both the brewpub open wort receiver and the enclosed airless grant. Wetted parts are 316 Stainless Steel. Learn More
Temperature probe used to sense current product temperature. To be used in conjunction with a temperature controller. Sensors have a spring-loaded probe designed to fit a 12 in. tempwell with a 1/2 inch MNPT fitting. Learn More
The low level sensor is an on/off float switch. The float should mount at the low level limit of a tank. Most commonly used in a hot liquor tank. Learn More
Thermometer face is 3IN. diameter and has a 1/2 in. MNPT threaded connection. 4IN stem. Rear mounted. Temperature range reads from 0 to 250 deg. F Learn More
Thermometer face is 3IN. diameter and has a 1/2 in. MNPT threaded connection. 12IN stem. Rear mounted. Temperature range reads from 0 to 250 deg. F Learn More
Thermometer face is 5IN. diameter and has a 1/2 in. MNPT threaded connection. 9IN stem. Rear mounted. Temperature range reads from 0 to 250 deg. F Learn More