The P.R.V. attaches to a 3IN TC vent.
Valve relieves pressure as the fluid level rises while filling a tank
Valve relieves vacuum as the fluid level drops while emptying a tank
Seals under equal pressure
Full body 316 stainless steel construction
1/4" FNPT connection for gas inlet, plug is included
Vacuum break: , 0.1 PSI
Pressure relief: 0.9 PSI
Maximum temperature and pressure rating: 3 PSI @ 70°F
Maximum flow rate: 500 GPM Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information. Learn More
The P.R.V. attaches to a 2 IN. TC vent or P.A.M. assembly. The valve is easy to take apart and clean. 15 lb. and 25 lb. pressure springs are available. Relief pressure can be adjusted down 5 lb. The valve will open at 0.089 lb. of vacumm. Full stainless steel body construction.
Material: Silicone Learn More
The P.A.M. Spool Assembly groups the necessary fittings together for tank pressure regulation. The standard spool assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 60.00 PSIG @ 200°F
TYPE SR-H Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 75PSIG @ 75°F Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 110.00 PSIG @ 200°F
TYPE AXIUS SC Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 1 1/2IN TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 130.0 PSIG @ 300°F Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 88.3 PSIG @ 72°F
SR-H TYPE Learn More
The rupture disc fits between 2IN TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Replace the disk every 5-6 years depending on the use of the tank to ensure superior performance. Learn More
The P.R.V. attaches to a 2 in. TC vent or P.A.M. assembly. The valve is easy to take apart and clean. 15 lb. and 25 lb. pressure springs are available. Relief pressure can be adjusted down 5 lb. The valve will open at 0.089 lb. of vacumm. Full stainless steel body construction. Learn More
The P.R.V. attaches to a 2 IN TC vent or P.A.M. assembly. The valve is easy to take apart and clean. 15 lb. and 25 lb. pressure springs are available. Relief pressure can be adjusted down 5 lb. The valve will open at 0.089 lb. of vacumm. Full stainless steel body construction. Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More