The DIN nut accompanies the plain DIN ferrule and is tightened with a DIN wrench. The nut serves the same function as a clamp in a TC connection. 304 SS mat. Metric sizes available. Learn More
The DIN ferrule is one side of a three piece DIN connection. Slip the DIN nut on the tubing before welding the ferrule in place. 304 SS mat. Metric sizes available. Learn More
The Sani-Spin is used much the same way as a C.I.P. sprayball. The advantage of the Sani-Spin is the force of it’s spinning action and the minimal volume it requires. For example, the optimum operating condition for a C.I.P. sprayball is 40 GPM @ 25 PSI; where as the Sani-Spin requires just 25 GPM @ 30 PSI. Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 60.00 PSIG @ 200°F
TYPE SR-H Learn More
The TC clamp is used to clamp two TC ferrules together. A TC gasket is installed between the ferrule for a complete seal. 304 Stainless Steel. Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 75PSIG @ 75°F Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 110.00 PSIG @ 200°F
TYPE AXIUS SC Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 1 1/2IN TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 130.0 PSIG @ 300°F Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 88.3 PSIG @ 72°F
SR-H TYPE Learn More
The rupture disc fits between 2IN TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Replace the disk every 5-6 years depending on the use of the tank to ensure superior performance. Learn More
The TC clamp is used to clamp two TC ferrules together. A TC gasket is installed between the ferrule for a complete seal. 304 Stainless Steel. Learn More
The TC clamp is used to clamp two TC ferrules together. A TC gasket is installed between the ferrule for a complete seal. 304 Stainless Steel. Learn More
The Fuji controller receives information from the temperature sensor and sends open/close signals to the Heat Transfer Jacket solenoid valve. It can also operate direct fire Burners/Immersion Heaters/Etc. Learn More
Temperature probe used to sense current product temperature. To be used in conjunction with a temperature controller. Sensors have a spring-loaded probe designed to fit a 12 in. tempwell with a 1/2 inch MNPT fitting. Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat.
DIA X 1IN DIA SLIP JOINT BOTTOM SPRAY PATTERN 316L Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More