The DIN threaded ferrule is one side of a three piece DIN connection. The threaded ferrule connects to the female threaded DIN nut. 304 SS mat. Metric sizes available. Learn More
The TC clamp is used to clamp two TC ferrules together. A TC gasket is installed between the ferrule for a complete seal. 304 Stainless Steel. Learn More
The TC clamp is used to clamp two TC ferrules together. A TC gasket is installed between the ferrule for a complete seal. 304 Stainless Steel. Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More
The Sani-Spin is used much the same way as a C.I.P. sprayball. The advantage of the Sani-Spin is the force of it’s spinning action and the minimal volume it requires. For example, the optimum operating condition for a C.I.P. sprayball is 40 GPM @ 25 PSI; where as the Sani-Spin requires just 25 GPM @ 30 PSI. Learn More
The Sani-Spin is used much the same way as a C.I.P. sprayball. The advantage of the Sani-Spin is the force of it’s spinning action and the minimal volume it requires. For example, the optimum operating condition for a C.I.P. sprayball is 40 GPM @ 25 PSI; where as the Sani-Spin requires just 25 GPM @ 30 PSI. Learn More
The DIN ferrule is one side of a three piece DIN connection. Slip the DIN nut on the tubing before welding the ferrule in place. 304 SS mat. Metric sizes available. Learn More
The DIN ferrule is one side of a three piece DIN connection. Slip the DIN nut on the tubing before welding the ferrule in place. 304 SS mat. Learn More
The DIN ferrule is one side of a three piece DIN connection. Slip the DIN nut on the tubing before welding the ferrule in place. 304 SS mat. Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
The Fuji controller receives information from the temperature sensor and sends open/close signals to the Heat Transfer Jacket solenoid valve. It can also operate direct fire Burners/Immersion Heaters/Etc. Learn More
The Fuji controller receives information from the temperature sensor and sends open/close signals to the Heat Transfer Jacket solenoid valve. It can also operate direct fire Burners/Immersion Heaters/Etc. Learn More
The P.A.M. Tree assembly groups the necessary fittings for tank pressure regulation together at the end of the vent extension line. The standard tree assembly consists of a pressure gauge, ball valve, and an open TC port. Does not include a P.R.V. Learn More
Motor Protection Circuit Breaker, C Frame, 1.6 - 2.5A, Trip Class 10, Standard Breaking Capacity, Std Mgntc Trp (Fxd at 14 x le) #140MT-C3E-B25
* Actual product may vary from image Learn More