Use a clevis pin as part of a clevis fastener. When threaded through the prongs of a tang and secured with a cotter pin, this fastening system allows movement along one axis while restricting it along the other. The clevis pin is used on the following ICC NW manways - 16X22 Shroud / Flushmount. Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 60.00 PSIG @ 200°F
TYPE SR-H Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat.
DIA X 1IN DIA SLIP JOINT BOTTOM SPRAY PATTERN 316L Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 75PSIG @ 75°F Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 110.00 PSIG @ 200°F
TYPE AXIUS SC Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 1 1/2IN TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 130.0 PSIG @ 300°F Learn More
A rupture disc is a secondary non-mechanical pressure protection system for your tank. The rupture disc fits between 2 in. TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Ask for a cut sheet for more information.
RATED 88.3 PSIG @ 72°F
SR-H TYPE Learn More
The P.R.V. attaches to a 2 in. TC vent or P.A.M. assembly. The valve is easy to take apart and clean. 15 lb. and 25 lb. pressure springs are available. Relief pressure can be adjusted down 5 lb. The valve will open at 0.089 lb. of vacumm. Full stainless steel body construction. Learn More
The rupture disc fits between 2IN TC fittings. It does not need a separate gasket. A rupture disc will protect your brewery and your patrons. It is extremely unwise and dangerous to operate a pressure tank without non-mechanical protection from over pressurization. Replace the disk every 5-6 years depending on the use of the tank to ensure superior performance. Learn More
The tank light is used to illuminate the inside of a vessel while brewing or cleaning. It mounts to a 2 in. TC fitting. A standard 120 volt circuit and a 50 watt bulb are required. Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More
Sprayballs are used either for dispersing cleaning solution into a tank, or sparging onto a lauter tun grain bed. The sprayball slips onto tubing with a hairpin clip. 2-1/2 in. sprayballs slip over 1 in. tubing and will clean up to 5 foot diameter vessels. 3-1/2 in. sprayballs slip over 1-1/2 in. tubing and will clean up to 10 foot diameter vessels. Optimum operation: 40 GPM @ 25 PSI. 316 SS mat. Learn More
The hi-low level control is used to regulate wort receiver levels. Commonly used on both the brewpub open wort receiver and the enclosed airless grant. Wetted parts are 316 Stainless Steel. Learn More
The Sani-Spin is used much the same way as a C.I.P. sprayball. The advantage of the Sani-Spin is the force of it’s spinning action and the minimal volume it requires. For example, the optimum operating condition for a C.I.P. sprayball is 40 GPM @ 25 PSI; where as the Sani-Spin requires just 25 GPM @ 30 PSI. Learn More
Heavy-duty 7ga outswing door and wing nuts swing free and clear of opening. Stainless steel wing nut assembly for extra strength with brass-lined wing nuts to prevent galling. Double cross arm for strong seal. Learn More